Shipped from Kyiv, UkraineWorldwide tracked shipping30-day returns
RetroSweetlo
Cart

K40Y-9

In stock19 listings from $2.00

Read text version
Text version ShowHide

K40U-9 capacitor datasheet

At a glance, page 1
HeadingHermetically sealed paper capacitors
TypeHermetically sealed paper-foil capacitors
Designed forUse as built-in components for internal wiring of equipment in DC, AC, pulsating current circuits and in pulse operating modes

K40U-9 outline drawing

Page 1 draws the capacitor from the side: a body with bevelled corners and a lead coming out of each end. D is marked across the body and L along it. The drawing prints no unit.

  • L runs between the two end faces of the body.
  • Each lead is dimensioned 25, from the end face of the body to the end of the lead. This includes the short piece, wider than the lead, where the lead leaves the body.
  • On the left lead, a dimension line across the lead is marked Φ0.6 on one side and 0.8;1 on the other, both printed sideways.

D and L are given in the table under Dimensions, mm.

Loss tangent, insulation resistance and time constant

Page 1 prints these under the drawing, without a heading of their own:

ParameterValue
Loss tangent, max0.01
Insulation resistance lead-to-lead under normal climatic conditions (up to 0.22 µF), min20,000 MΩ
Time constant under normal climatic conditions (above 0.22 µF), min4000 MΩ·µF
Insulation resistance lead-to-case, min5000 MΩ

Maximum operating ratings

From page 1:

Maximum operating ratings
Ambient temperature−60 to +125°C
Relative humidity at a temperature of 35°CUp to 98%
Reduced atmospheric pressureDown to 0.0000013 hPa (10−6 mm Hg)

Further characteristics

The last block on page 1 has no heading:

ParameterValue
Minimum operating life10,000 h
Capacitance change, max±10%
Loss tangent, max0.06
Insulation resistance lead-to-lead (up to 0.22 µF), min10,000 MΩ
Time constant (above 0.22 µF), min2000 MΩ·µF
Insulation resistance lead-to-case, min2500 MΩ
Shelf life15 years

Capacitance, voltage, dimensions and mass

The table runs over pages 2 to 4, with the same column headings on each page. Where one cell lists several capacitances, each is given its own row. Where a cell spans several rows, its value is repeated in each.

200 V, page 2

Nominal capacitance, µFRated voltage, VD, mmL, mmMass, g (max.)
0.000472005182.5
0.000682005182.5
0.0012005182.5
0.00152005182.5
0.00222005182.5
0.00332005182.5
0.00472005182.5
0.00682005182.5
0.012006183
0.0332008215
0.04720010228
0.06820010228
0.120010289
0.15200103511
0.22200143017
0.33200163024
0.47200164228
0.68200184236
1.0200205248

400 V, pages 2 and 3

Nominal capacitance, µFRated voltage, VD, mmL, mmMass, g (max.)
0.00474006183
0.00684006183
0.0154008215
0.0224008215
0.03340010228
0.04740010289
0.068400103511
0.1400143017
0.1540016–24
0.22400164228
0.33400184236
0.47400185240
0.68400206255

Page 2 ends after the 0.1 µF row. At the top of page 3, the L cell of the 0.15 µF row is empty.

630 V, page 3

Nominal capacitance, µFRated voltage, VD, mmL, mmMass, g (max.)
0.000476306183
0.000686306183
0.0016306183
0.00156306183
0.00226306183
0.00336306183
0.00476308185
0.00686308185
0.016308215
0.01563010228
0.02263010289
0.03363010289
0.047630103511
0.068630143017
0.1630163024
0.15630164228
0.22630184236
0.33630205248
0.47630206255

The 0.0047 and 0.0068 µF cell shares its L cell, 18, with the six values above it, and its D cell, 8, and mass cell, 5, with the 0.01 µF row below it.

1000 V, pages 3 and 4

Nominal capacitance, µFRated voltage, VD, mmL, mmMass, g (max.)
0.001100010228
0.0015100010228
0.0022100010228
0.0033100010228
0.0047100010228
0.0068100010228
0.01100010289
0.015100010289
0.0221000103511
0.0331000143017
0.0471000163024
0.0681000163824
0.11000164230
0.151000185240
0.221000205248

The 0.001 and 0.0015 µF cell is the last on page 3; the other rows are on page 4. On page 4 the L value 52 is printed once, in a cell that spans the 0.15 and 0.22 µF rows.

The note under the table on page 4: Note. Tolerances: ±10%; ±20%.

Allowable AC voltage vs. frequency

The chart on page 4 is titled: Dependence of allowable amplitude of AC voltage (1) and allowable amplitude of the AC component of pulsating voltage (2) on frequency.

It plots Uf/Uн, % against f, Hz. The left scale is marked 0, 2, 5, 10, 20, 50 and 60. The bottom scale is marked 50, 102, 2·102, 5·102, 103, 2·103, 5·103 and 104, and the last label, at the right-hand edge, is printed as 2·10.

  • Two lines run near the top, the upper one starting level at 60 and the lower one at 50. The labels 200;400 V and 630;1000 V, with short leader lines, sit above them. Both slope down from near the 50 Hz line, drop more steeply between 5·102 and 103, slope down more gently again up to 104, then fall steeply and meet at the right-hand edge, where they are marked 1.
  • The third line starts level at 20, then falls in a straight line from the 50 Hz line to the right-hand edge, ending just above the bottom of the grid. It is marked 2.

Back to the scans

Resources

More ways to explore

Documentation

All Datasheets

Browse our complete library of technical specifications and documentation.

Browse Datasheets

Products

Browse Catalog

Explore our full inventory of vintage tubes, nixies, and capacitors.

View Products

Questions?

Contact Us

Need help finding the right part or datasheet? We're here to help.

Get in Touch
Contact